Description
KL5-0.5-105 Stationary anode X-Ray Tube is especially designed for panoramic dental x-ray unit and available for a nominal tube voltage 105kV with single-phase full-wave rectified or DC circuit The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode. The high anode heat storage capacity ensures a wide range of applications for panoramic dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.Technical data
Nominal Tube Voltage | 105kV |
Nominal Inverse Voltage | 115kV |
Nominal Input Power(at 1.0s) | 950W |
Max. Anode Cooling Rate | 250W |
Max. Anode Heat Content | 35kJ |
Filament Characteristics | Ifmax3.5A,5.5±0.5V |
Nominal Focal Spot | 0.5 (IEC60336/2005) |
Target Angle | 5° |
Target Material | Tungsten |
Cathode type | W filament |
Permanent Filtration | Min. 0.5mmAl/50 kV(IEC60522/1999) |
Dimensions | 140mm length by 42mm diameter |
Weight | 380 grams |
Competitive Advantage
Elevated anode heat storage capacity and cooling Constant high dose yield Excellent lifetimeApplications
KL5-0.5-105 Stationary anode X-Ray Tube is especially designed for panoramic dental x-ray unit and available for a nominal tube voltage 105kV with single-phase full-wave rectified or DC circuit.Detailed Images
Cautions
Read the cautions before using the tube
X-ray tube will emit X –ray when it is energized with high voltage, Special knowledge
should be required and cautions need to be taken when handling it。
1. Only a qualified specialist with X-Ray tube knowledge should assemble, maintain
and remove the tube。
2. Sufficient care should be taken to avoid strong impact and vibration to the tube
because it is made of fragile glass。
3. Radiation protection of the tube unit must be sufficiently taken。
4. The minimum sorce-skin distance (SSD) and the minimum filtration should match the
regulation and meet the standard。
5. The system should have proper overload protection circuit , the tube may be
damaged due to only one overload operation。
6. When any abnormalities are found during operation , immediately switch off the
power supply and contact the service engineer。
7. if the tube is with a lead shield, to dispose of lead shield must meet government
regulations。